Aton DLA6 Manuale Utente

Pagina di 42
 © 2008 • All rights reserved.                                                                              27
DLA2/4/6 Speaker Level Audio Router
Symptom
Possible Cause
Solution
Volume only ramps to 10
4 Ohm Speaker con-
nected to 8 Ohm-rated 
ampli er.
Normal operation. Func-
tions this way to protect 
ampli er.
IR Control
Symptom
Possible Cause
Solution
No source control in a 
Room from IR port
1. Wiring: IR signal not 
reaching Room input.
Check Room IR receiver 
and verify wiring.
2. Remote Control bat-
teries are dead.
Replace batteries.
No source control in any 
Room.
1. See above.
Perform steps above.
2. Source IR Emitters 
unplugged or defective.
Reconnect or test with 
known good IR Emitters.
Intermittant source 
control.
Mild to moderate IR 
Flooding.
Check IR indicator on 
front panel. If it  ickers, 
IR  ooding is indicated. 
Check any IR receivers 
that may be receiving 
ambiant light or plasma 
TV noise.
Room appears to be on 
and selected but unabled 
to be controlled using 
front panel buttons.
Extreme IR  ooding.The 
IR indicator will be solid 
red when the room is off, 
solid off when the room 
is on, or solid purple 
when the room is on and 
unselected. 
Perform steps above.