Atlas Copco Stationary Air Compressors Manuale Utente

Pagina di 70
Instruction book 
2920 1521 00 
48 
2.  By pressing the 
↓ key, a number of actually measured data can be found (see Fig. 8.1). 
3.  If one of the sensors is linked to a shut-down, service or warning function, both the actually 
measured value as well as the corresponding shut-down, warning or service level can be called up 
by pressing the tabulator key (5). 
 
 
8.5 Counters menu 
 
Function 
 
To allow the operator to call up the: 
- running 
hours 
regulator (module) hours (the hours the module has been under tension) 
running hours per compressor module 
starts per compressor module 
shutdowns per compressor module 
 
Procedure 
 
1.  Starting from the Main screen (see section 8.1.2): 
press the key "Menu" (F1) 
- press 
the 
↓ key until the option "Counters" is followed by a horizontal arrow 
press the tabulator key (5) to activate the menu 
2.  By pressing the 
↓ key, the above-mentioned data can be found (see also Fig. 8.1). 
 
 
8.6 Test menu 
 
Function 
 
To carry out a display test, i.e. to check whether the display and LEDs are still intact. 
 
Procedure 
 
1.  Starting from the Main screen (see section 8.1.2): 
press the key "Menu" (F1) 
- press 
the 
↓ key until the option "Test" is followed by a horizontal arrow 
press the tabulator key (5) to activate the menu 
2.  The option "Display test" will be followed by a horizontal arrow. 
3.  After pressing the tabulator key (5), the regulator will generate a series of patterns on the display 
which enable the operator to check that each pixel still functions normally; at the same time the 
LEDs are lit.