Atlas Copco Stationary Air Compressors Manuale Utente

Pagina di 70
Instruction book 
2920 1521 00 
62 
3.  Press the tabulator key (5): 
 
Next Timer 
 
 
 
Level  
ABI 
 
  10000 
hrs 
↓ 
Back  
Reset 
 
F1 F2 F3 
 
 
Fig. 8.20 Service menu, typical example 
 
 
The screen shows that the next service plans to be carried out are plans A, B and I and that these 
plans are to be carried out each 10000 running hours. 
 
 
4. Press 
the 
↓ key to find which service plans were carried out previously: 
 
Previous Timer 
 
 
↑ 
Level  
AI 
 
  5008 
hrs 
 
Back  
 
 
F1 F2 F3 
 
 
Fig. 8.21 Service menu, typical example 
 
 
The screen shows that service plans A and I were carried out at 5008 running hours. 
 
5.  Stop the compressor, switch off the voltage and carry out the service operations related to plans 
A, B and I. 
6.  Switch on the voltage and scroll to the service screen shown in Fig. 8.20.  Press the "Reset" 
button (F3) to reset the timer.  Confirm the question for resetting. 
 
 
Notes 
-  The "Reset" button only appears when the next Timer level is almost reached (from 400 
running hours before elapsing of the service plan interval). 
After pressing the 
↓ key in Fig. 8.19, the Life time hours are shown (i.e. the number of hours 
elapsed since initial programming ex-factory).  This counter is not taken into account.