Artesian Spas Grand Bahama Manuale Utente

Pagina di 88
ELECTRICAL REQUIREMENTS 
AND INSTALLATION
The following information is provided for hooking up electrical supply to 
your new spa. A qualified, licensed, electrician must perform this work. 
Failure to follow these instructions will terminate all warranty coverage 
and can cause serious injury or death.
Your 60Hz Artesian spa is preset at the factory to run on 240V with a  48 
amp maximum input. This feature gives you the most performance out 
of your spa. This will require a 240V, 60-amp GFCI. If a 60-amp service 
is  not  available,  please  contact  the Artesian  Spas’  Customer  Service 
department to configure the amp draw requirements.
ELECTRICAL WIRING
WARNING:  Your spa must be wired by a certified electrician and 
according to these  instructions. Failure to do so will terminate all 
warranties and all listings from the independant listing facility.
1) The Island Class Spa requires a 240 VAC dedicated system. The spa 
must  be  hardwired  to  the  power  supply,  with  no  plug-in  connections, 
extension cords, or sharing of service.
2) The spa requires that you run 6 or 8 AWG copper wire, depending on 
the GFCI size. Do Not Use Aluminum Wire.
3) The power supply must have a suitable Ground Fault  Circuit Inter-
rupter  (GFCI),  according  to  Section  422-20  of  the  National  Electrical 
Code, ANSI/NFPA 70-7987. This could be used as the shut-off switch, 
which must be installed in plain view of the spa. This electrical service 
must be readily accessible to the spa occupants, but must not be within 
5 feet of the spa. 
4) Use only non-metallic conduit and fittings when installing power to 
the spa.
5) After your spa has been positioned, route lines through the knockout  
    on the left or right front corner of the spa.
6) Connect the power to the spa.
42