Diagnostic Messages
57
Temperature unknown. 
After  the  pump  has  been  running  for  2  minutes,  the 
temperature will be displayed
“Overheat” - The spa has shut down.  One of the 
sensors has detected 118°F/48°C at the heater. 
DO NOT ENTER THE WATER.  Remove the spa cover 
and  allow  water  to  cool.    Once  the  heater  has  cooled, 
reset by pushing any button.  If spa does not reset, shut 
off the power to the spa and call your dealer or service 
organization.
“Overheat” - The spa has shut down.  One of the 
sensors has detected that the spa water is 110°F/43°C. 
DO  NOT  ENTER  THE  WATER.    Remove  the  spa 
cover and allow water to cool.  At 107°F/42°C, the spa 
should  automatically  reset.  If spa does not reset, shut 
off the power to the spa and call your dealer or service 
organization
“Ice” - Potential freeze condition 
No action required.  The pump and blower will automatically 
activate regardless of spa status.
Spa is shut down.  The sensor that is plugged into the 
Sensor “A” jack is not working. 
If  the  problem  persists,  contact  your  dealer  or  service 
organization.    (May  appear  temporarily  in  an  overheat 
situation and disappear when the heater cools.)
Spa is shut down.  The sensor that is plugged into the 
Sensor “B” jack is not working.
If  the  problem  persists,  contact  your  dealer  or  service 
organization.    (May  appear  temporarily  in  an  overheat 
situation and disappear when the heater cools.)