Aquacal HP7 Manuale Utente

Pagina di 29
 
WARNING !!!!  Dealer &  Service Center Use Only 
Installing a Call Flex Kit 
Appendix- D 
 
Installing a Call Flex Kit 
for 
Time Clock Management - Heaters Equipped With HP7 Microprocessor 
 
 
The CALL-FLEX is installed to manage the time clock to the desired heating style of the pool heat 
pump owner. With CALL-FLEX, owners select one of three heat modes: 
 
 
Call Mode 
  
  The heater "overrides" the filter pump timer when the pool water drops below the 
temperature set point. Two hours after the initial thermostat "call" for heat, the 
heater starts. This delay prevents nuisance pool pump cycling. 
 
In CALL MODE, the heater will operate mostly at night when the greatest heat loss 
occurs and the heater is least effective. If the owner prefers daytime operation, 
the FLEX MODE may be more productive. 
 
Flex Mode 
 
The heater "extends" the heating hours beyond the timer settings. If the heater is 
not running when the time clock expires, the pool pump will remain off until the 
next timed cycle. If running, it continues the pool and heater operation until the 
set point is attained, then stays off until the next timed cycle. 
 
The FLEX MODE is very convenient after cold snaps, if the blanket was left off the 
pool, or at initial start-up when the heater must run beyond standard filtering hours to 
elevate the pool temperature. 
 
Off Mode 
 
Operation is controlled by the time clock. 
 
 
 
 
 
 
 