START UP & SETTING OPERATING CONTROLS 
LEVEL-1 (Owner) ACCESS 
  
 
 
NOTE:  
Covered within this section are features and settings typically accessed first by 
the installer, and then remaining accessible by the end user (owner).  These 
features reside at the Level-1 access point within the microprocessor.  (Please 
see page-11
 
 for information concerning Level-2, service-related access.) 
       
 
1. 
Applying Power to The Controller: 
 
 
A.  When power is first applied, the control performs a lamp test and the display will read 
[888]. Following [888], and with versions .04 and greater, the software version will 
display briefly.  Additionally, all status LED’s lights will illuminate for 4 seconds and 
then go off for 1 second. 
 
B.  The control will then display the actual temperature as long as the pool-circulating pump 
is on.  
 
C.  If the pool-circulating pump is off, the control will display the [FLO] (No Water Flow) 
code message indicating water is not being circulated though the heat pump. 
 
2. 
Turning The Heat Pump ON: 
   
 
A.  Once electrical power is supplied to the heat pump, the pool-circulating pump is 
activated, and the control has successfully completed the self-test, the unit is ready to 
operate.  
 
B.  The control is shipped with the SPA set point in the [OFF] mode and with the POOL set 
point selected. The heat pump is automatically switched off if a set point below 60 °F 
has been selected. In the [OFF] mode, the control will display the water temperature as 
long as the pool water-circulating pump is operational. In the event water is not 
circulating through the heat pump, the control will display the [FLO] (No Water Flow) 
code message.  
 
C.  Using the Up 
⇑ arrow key, increase the desired temperature until it exceeds the value of 
the actual temperature displayed. (Note: See #8, below,  if  “000” is displayed upon 
pressing up or down arrows.) 
Once the desired temperature has been entered, the display 
will read the actual temperature and the heat pump will start to operate. Both the 
compressor and fan must be operating before the “Heat” LED will illuminate.  
 
3. 
Turning The Heat Pump OFF: 
   
 
A.  Using the Down 
⇓ arrow key, decrease the desired temperature until the display reads 
[OFF]. The heater will shut off,  and will remain off until the temperature set point is 
raised above 60
° F.  
 
B.  NOTE:  Each time the heater is turned off, either manually, or by the thermostat 
becoming satisfied, there will be a 4-minute delay prior to restarting. 
 
4. 
Selecting Pool / Spa Thermostat Settings: 
 
A.  Depress the Pool / Spa key to toggle between the pool and spa temperature set points. 
 
B.  The pool / spa led indicator lights located to the left of the temperature display will 
confirm the selected temperature set point.