4-57
Apex 1 to 5.5 kW Generator
219
report 
condensed 
snapshot of 
generator 
data
Returns the condensed snapshot of generator 
data
Note: The response contains 2 sets of 
responses for APEX with Directional 
Coupler and VI System. 
For Directional coupler the data points 
are:
• 0,1: Forward Power with Bias 
Correction
• 2,3: Reflected Power with Bias 
Correction
• 4,5: Delivered Power with Bias 
Correction
• 6,7 User Setpoint
• 8: Regulation Mode (see command 3 for 
definition)
• 9 to 12: Process Status (see command 
162 for definition)
• 13,14: Cold Plate Temperature (see 
command 228 for definition)
• 15,16: DC Voltage
• 17,18: DC current
• 19 to 22: Unused 
APEX with VI Measurement data point 
definitions:
• 0,1: Real Power with Bias Correction
• 2,3: Imaginary Power with Bias 
Correction’
• 4,5:VSQ with Bias Correction
• 6,7: User Setpoint
• 8: Regulation Mode (see command 3 for 
definition)
• 9 to 12: Process Status (see command 
162 for definition)
• 13,14: Cold Plate Temperature (see 
command 228 for definition)
• 15,16: DC Voltage
• 17,18: DC Current
Table 4-6. Host Port Commands for RS-232 with AE Bus  (Continued)
Command
Description
Number of 
Host Data 
Bytes
Number of 
Response 
Data Bytes