Installing the Outdoor Unit 
Installation 
 
49
2.3.5  Connecting the Indoor-to-Outdoor Cable 
2.3.5.1 
Units with an Installed Waterproof Seal (not applicable to 
new ODU) 
 
To connect the indoor-to-outdoor cable: 
Remove the two screws holding the waterproof seal to the outdoor unit and 
remove the waterproof seal. 
Unscrew the top nut from the waterproof seal. 
 
Figure 2-10: The Waterproof Seal 
Route a straight Category 5E Ethernet cable (8-wire, 24 AWG) through both 
the top nut and the waterproof seal.  
 
 
 
NOTE 
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer. See list of 
approved cables and length limitations in section 
2.1.2
Insert and crimp the RJ-45 connector. Refer to Appendix D for instructions 
on preparing the cable. 
Connect the Ethernet cable to the outdoor unit RJ-45 connector. 
Replace the waterproof seal and then the top nut. Make sure that the external 
jack of the cable is well inside the waterproof seal to guarantee a good seal. 
Route the cable to the location selected for the indoor equipment. 
Assemble an RJ-45 connector with a protective cover on the indoor end of the 
indoor-to-outdoor cable.