Alvarion BREEZENET BU-DS.11 Manuale Utente

Pagina di 92
The DS.11 Configuration Utility 
 
 
 
3-31 
Resetting the SNMP Community 
Strings 
The SNMP Read/Write Community strings serve as an SNMP security feature to 
restrict management access to authorized persons only.  
To reset the SNMP community strings, insert a paper clip or another suitable tool 
into the Reset button on the top panel of the unit and press the button it for than 
one second at least (see Figure 
2-6 on page 2-13) while the unit is operating. After 
one more second the community strings are reset to the default values, private 
(Read/Write) and public (Read). 
Reloading Factory Default Settings 
 
To reset the unit to the factory defaults: 
1. 
Disconnect the power cable from the indoor unit. 
2. 
Insert a paper clip or another suitable tool into the Reset button on the top 
panel of the unit (see Figure 
2-6 on page 2-13). Keep the Reset button pressed 
while inserting the power cable back into its socket. Keep the Reset button 
pressed for at least 3 seconds after reinserting the power cable. After one more 
second the unit will be reset to its factory default configuration.