5.5 
REPLACING
 
THE
 
POWER
 
PCB 
 
Place  the  machine  onto  one  side  which  will  expose  the  service  cover 
panel, remove the 2 screws and the panel with the power PCB attached 
will come away, remove the PCB cover and faulty PCB and replace with 
a new one. 
5.6
 
REPLACING
 
SENSORS 
When replacing a sensor the old one will need to be removed and the 
new  one  fitted  to  the  PCB  or  mounting.  Various  screws  have  to  be 
removed to gain access to the sensors.  
The  START  sensor  can  be  changed  after  removing  the  note  feeder 
assembly as explained in section 5.1 
The  BATCH  sensor  can  be  changed  following  the  removal  of  the  2  x 
screws on the front underside of the machine. The new sensor will have 
to be fixed using hot melt glue. 
The  UV,  MG  and  also  the  LEFT  and  RIGHT  sensors  can  be  changed  by 
accessing  them  from  the  front  and  also  from  the  top  of  the  machine. 
The display unit will need to be  pulled forward to expose the top part 
for access. 
 
5.7 
 
SENSOR
 
POSITION
 
PICTURE