Adam Equipment TV Mount ncsa 20 Manuale Utente

Pagina di 20
 
Adam Equipment Company 2012 
 
 
If  any  of  the  error  messages  appear  please  check  to  ensure  the  sensors  are 
clean  and  the  areas  around  them  are  clear.  Clean  with  a  soft  cloth  and  dust 
the area with a brush. If the problem persists please contact your dealer. 
An adjustment can be made to suit the thickness of the note being counted by 
turning the special spring tensioned screw located under the note tray at the 
rear of the counter. 
Turn  this  screw  clockwise  for  a  thinner  note  and  anti  clockwise  for  a  thicker 
note. 
                            
 
5.0
 
SERVICE
 
INFORMATION 
Replacement of parts may be necessary when faults occur, the error codes in 
table 4.1 help determine where some of the faults may lie and the following 
information is a guide how to remove and replace them. 
 
5.1 
REPLACING
 
THE
 
FEED
 
ROLLERS 
Unscrew the note feeder adjusting screw as far as you can and pull hard  
towards you on the note feeder assembly. The assembly should come 
out exposing the feed rollers and assembly shaft. Pull the note feeding 
guide upwards which should then also come out. Remove the two outer 
covers by unscrewing the 5 x screws that attach each one. Remove the 
circlip at each end of the shaft and push the shaft through to enable 
easy removal of the feed rollers. Removing the large drive belt may also 
make this easier to do.