Scanner Options
 
Scamax 2600 / 5000
 
DpuScan
 
Patchcode returns these values: 
 0 Patch 
 1 Patch 
II 
 2 Patch 
III 
 3 Patch 
 4 Patch 
IV 
 5 Patch 
VI 
Endorsed (0 or 1) 
 
Note: 
All multi-digit numbers will be aligned to the right without any leading zeros. The format is completely 
independent of the formats chosen for the printout. 
 
5.2.2 Image 
Address 
The image address is the part of the header that is sent to the application software with each image. 
From left to right, it consists of the following parts: 
Fixed Text 
Bytes 109 -118 
Counter C (Volume Counter) 
Bytes 120 -129 
Counter B (Chapter Counter)  Bytes 131 -140 
Counter A (Page Counter) 
Bytes 142 -151 
All parts have 10 digits each and are separated by a point. Numbers will be aligned to the right. 
 
5.2.3 Counters 
Up to four counters can be managed. The name of the counters is based on the idea that there are 
many "Pages" building several "Chapters". "Chapters" build "Volumes" which will be stored on "Film 
Rolls".  
Of course, these names should show the grouping and hierarchy only. Therefore, in another context 
they may be called "Document Counter", "Enclosure Counter", "File Counter", etc. 
This step in the document hierarchy is called Level.  
The change from one level to another will be marked either by separator sheets with printed 
Patchcodes, or will occur after a fixed number of pages. 
Page Counter A 
This counter will be incremented automatically by 1 for every scanned front side and back side of a 
document.  
Only after an event that resets the counter can it be incremented "manually" by the user-defined 
value. After the first image, the counter will be incremented by 1 again automatically. 
Page 19 of 42