Chapter 6 Checking LEDs
6-5
A similar situation occurs when you add an expansion unit or JBOD and there is a 
mismatch between the SES or PLD firmware of the RAID array and that of the 
expansion unit, or between two expansion units.
See  “Upgrading SES and PLD Firmware” on page 7-8 for information about 
upgrading SES and PLD firmware.
6.3
Back-Panel LEDs
The back-panel LED colors indicate the conditions described in the following figures 
and tables. 
Note – 
To test that the LEDs work, using a paper clip, press and hold the Reset button 
for 5 seconds. All the LEDs should change from green to amber when you perform this 
test. Any LED that fails to light indicates a problem with the LED. When you release 
the Reset button, the LEDs return to their initial state.
6.3.1
I/O Controller Module LEDs
Figure 6-3 shows the SANnet II 200 FC array I/O controller module and the LEDs on 
its back panel.
Figure 6-3  SANnet II 200 FC Array I/O Controller Module and Battery Module 
LEDs
Figure 6-4 shows the SANnet II 200 SATA array I/O controller module and the LEDs 
on its back panel.
Ethernet active
Ethernet link
Battery
SFP link status
SFP speed
RAID controller status
I/O activity
Cache