Dot Hill Systems II 200 FC Manuale Utente
Chapter 6 Checking LEDs
6-5
A similar situation occurs when you add an expansion unit or JBOD and there is a
mismatch between the SES or PLD firmware of the RAID array and that of the
expansion unit, or between two expansion units.
mismatch between the SES or PLD firmware of the RAID array and that of the
expansion unit, or between two expansion units.
See “Upgrading SES and PLD Firmware” on page 7-8 for information about
upgrading SES and PLD firmware.
upgrading SES and PLD firmware.
6.3
Back-Panel LEDs
The back-panel LED colors indicate the conditions described in the following figures
and tables.
and tables.
Note –
To test that the LEDs work, using a paper clip, press and hold the Reset button
for 5 seconds. All the LEDs should change from green to amber when you perform this
test. Any LED that fails to light indicates a problem with the LED. When you release
the Reset button, the LEDs return to their initial state.
test. Any LED that fails to light indicates a problem with the LED. When you release
the Reset button, the LEDs return to their initial state.
6.3.1
I/O Controller Module LEDs
Figure 6-3 shows the SANnet II 200 FC array I/O controller module and the LEDs on
its back panel.
its back panel.
Figure 6-3 SANnet II 200 FC Array I/O Controller Module and Battery Module
LEDs
Figure 6-4 shows the SANnet II 200 SATA array I/O controller module and the LEDs
on its back panel.
on its back panel.
Ethernet active
Ethernet link
Battery
SFP link status
SFP speed
RAID controller status
I/O activity
Cache