Dot Hill Systems II 200 FC Manuale Utente

Pagina di 210
A-4
SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
A.2.3
Firmware LUN Filtering (RAID-Based Mapping)
LUN filtering is a method used for separating and controlling access to data from the 
RAID controller. One major benefit of Fibre Channel is the capability to share a 
common storage pool with multiple servers or workstations. However, allocation 
becomes an issue when every server in a network can access the data in a logical drive. 
LUN filtering provides a means for controlling data access if data is not allowed for 
every server. 
When you map a logical drive to a host LUN through the firmware application, you 
can create a mapping according to the worldwide port names (WWPN) that are 
specific to each host adapter. A LUN mask can then be created as an access filter for 
including or excluding host adapters from addressing specific storage unit. A host map 
is composed of an ID range that is configured to include one or more IDs. A host 
adapter can be identified by its ID (device-specific port names) as included or 
excluded from range. The LUN mask is also defined with a filter type as read only or 
read/write.
A.2.4
Firmware Redundant Loops
The selection of “drive-side dual-loop” is fixed. Since two channels are used to 
connect a group of physical drives, the two channels automatically assume the same ID 
address and operate in duplex mode.
A.2.5
Firmware Dynamic Load Balancing
The controller provides a mechanism to equally distribute I/O loads between channels 
in a redundant loop configuration.
A.3
Agency Approvals and Standards
Table A-3 SANnet II 200 FC, SATA, and SATA SE Array Product Safety & Electromagnetic 
Standards
Product Safety
Standard
Country
U.S.
UL Listed to UL60950:2000, 3rd Edition
Canada
CSA Standard CAN/CSA-C22.2 No. 60950-00 3rd Edition
Germany
TÜV 
European Union
EN 60950:2000
Japan
Part of World-wide CB Scheme