Figure E-1  RAID Array COM Port Connected Locally to the Serial Port of a 
Workstation
2. Power up the array.
It can take two or three minutes for both controllers to be initialized before 
communication is possible over the connection.
3. Set the serial port parameters on the workstation.
E.2
Using the tip Command for Local Access to 
the Array
You can access the RAID COM port (DB9 connector on the controller module) locally 
with the following steps. 
1. Connect the RAID array COM port to the serial port of a Solaris workstation, as shown 
in Figure E-1. Use the tip command to access the array locally:
 
where n is the COM port identifier. For instance, if you have connected the array to the 
COM port identified as ttyb, use this command:
 
2. Refresh your screen by holding down the Control key on your keyboard and pressing 
the letter L key on your keyboard.
tip -38400 /dev/ttyn
tip -38400 /dev/ttyb
COM port
COM port