Dot Hill Systems II 200 FC Manuale Utente

Pagina di 210
1-8
SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005
in a JBOD array. For example, “SANnet II 200 D1000” identifies a JBOD array with 
SES firmware version 1000 and “SANnet II 200F A1000” identifies a SANnet II 200 
FC RAID array with firmware version 1000.
For a list of supported racks and cabinets, refer to the SANnet II Family Rack 
Installation Guide for 2U Arrays
.
Reliability, availability, and serviceability (RAS) are supported by:
Redundant components
Notification of failed components
Components that are replaceable while the unit is online
For information about specifications and agency approvals, see “SANnet II 200 FC, 
SATA, and SATA SE Array Specifications” on page A-1.
1.2
Field-Replaceable Units 
This section describes the field replaceable units (FRUs) contained in the SANnet II 
200 FC, SATA, and SATA SE arrays.
1.2.1
RAID I/O Controller Modules
A dual-controller configuration offers increased reliability and availability because it 
eliminates a single point of failure, the controller. In a dual-controller configuration, if 
the primary controller fails, the array automatically fails over to the second controller 
without an interruption of data flow. 
The FC, SATA, and SATA SE array I/O controller modules are hot-serviceable. Hot-
serviceable
 means that the module can be replaced while the array and hosts are 
powered on, but the connected hosts must be inactive. 
SANnet II 200 FC array RAID controller modules provide six Fibre Channel ports.
SANnet II 200 SATA array I/O controller modules provide eight Fibre Channel 
ports.
SANnet II 200 SATA SE array I/O controller modules provide six Fibre Channel 
ports.
Single- and dual-controller models are available, with the dual-controller version 
supporting active/passive and active/active configurations. Each RAID controller is 
configured with 1 Gbyte of cache. 
In the unlikely event of an I/O controller module failure, the redundant RAID 
controller immediately begins servicing all I/O requests. The failure does not affect 
application programs.
Each RAID I/O controller module can support up to 1 Gbyte of Synchronous Dynamic 
Random Access Memory (SDRAM) with Error Control Check (ECC) memory. In 
addition, each controller supports 64 Mbyte of on-board memory. Two Application-