Husqvarna 1055 GN Manuale Utente

Pagina di 29
1 
www.usa.husqvarna.com
Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup, screen, 
retaining ring and o-ring that need to be cleaned every 100 
hours or once a year (whichever occurs first).
  1.  Move fuel valve to “Off” position.
  2.  Remove sediment cup (A) from fuel valve. Remove 
o-ring (B), retaining ring (C) and screen (D) from fuel 
valve.
  3.  Wash sediment cup, o-ring, retaining ring, and screen 
in a nonflammable solvent. Dry them thoroughly.
  4.  Place screen, retaining ring, and o-ring into fuel valve. 
Install sediment cup and tighten securely.
  5.  Move fuel valve to “On” position, and check for leaks. 
Replace o-ring if there is any leakage.
Engine Maintenance
 
WARNING
Unintentional sparking can result in fire or 
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO yOUR GENERATOR
•  Disconnect the spark plug wire from the spark plug and place 
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
•  Use approved spark plug tester.
•  DO NOT check for spark with spark plug removed.
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty 
Certified oils for best performance. Other high-quality 
detergent oils are acceptable if classified for service SF, SG, 
SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for 
the engine. Use the chart to select the best viscosity for the 
outdoor temperature range expected.
*  Below 40°F (4°C) the use of SAE 30 will result in hard starting.
**  Above 80°F (27°C) the use of 10W30 may cause increased oil 
consumption. Check oil level more frequently.
   NOTE: Synthetic oil meeting ILSAC GF-2, API 
certification mark and API service symbol with “SJ/CF 
ENERGY CONSERVING” or higher, is an acceptable 
oil at all temperatures. Use of synthetic oil does not 
alter required oil change intervals.
Checking Oil Level
Oil level should be checked prior to each use or at least 
every 8 hours of operation. Keep oil level maintained.
  1.  Make sure generator is on a level surface.
  2.  Clean area around oil fill and remove oil fill cap.
  3.  Verify oil is at the point of overflowing at oil fill 
opening.
  4.  Replace and tighten oil fill cap.
Adding Engine Oil
  1.  Make sure generator is on a level surface.
  2.  Check oil level as described in Checking Oil Level.
  3.  If needed, slowly pour oil into oil fill opening to the 
point of overflowing at oil fill.
  4.  Replace and tighten oil fill cap.
D
B
C
A