5.2 Operator Diagnostics 
This gate operator is designed with built-in diagnostics that will alert you to potential or existing 
problems that the microprocessor has detected.  Specific fault conditions are checked and the 
operator will signal that a fault exist through the built-in alarm. 
 
Constant tone is heard when power is applied: 
This indicates that the limit switch wire harness is not connected to the circuit board.  In this condition, 
the operator will not run and the tone will continue until the fault is corrected.  Check to be sure that 
the limit switch plug is properly inserted into P2. 
Constant tone is heard: 
This indicates that the operator is in a hard shutdown condition (section 4.2.3).  The tone will continue 
to sound for five minutes, and then will beep once every five seconds.  The operator-reset button 
must be pressed or power must be removed and then reapplied to return the operator to normal 
operation. 
Short tone is heard every five seconds: 
This indicates that the operator has been in a hard shutdown condition in excess of five minutes.  
This will continue until the operator-reset button is pressed or until power is removed from the 
operator. 
Operator runs for 1 second and stops, two short tones are heard: 
This indicates that there may be a fault with the current sensor circuit. 
 