Group Test Mode
Group test mode places the faders on Control|24 
in a test mode where the faders become grouped 
and can be moved, lock-step, to indicate that all 
faders are operating properly in a grouped fash-
ion. 
When “Grp” Fader Test Mode is Engaged:
• The encoder switch LED located below the 
scribble strip which shows “Grp” will light 
solid indicating that this is the chosen test 
mode.
• All other display test menu items shown on 
the scribble strips as well as their associated 
flashing encoder switch LEDs, will remain vis-
ible in this test mode. The scribble strip dis-
plays will toggle back and forth between the 
group cycle values, which allows you to select 
another display test mode without the need 
to first “Exit” this mode.
• Touch any fader and move the fader to any 
position on the fader path. All other faders 
will move, lock-step, to the position of the 
master. 
• The fader position value will be shown in 
these scribble strips and will be updated in 
real-time as the faders are moved in group 
mode. Values will range from off (value of 
“0000”) to full-on (value of “1023”).
• Press EXIT, or press the flashing encoder 
switch located below the scribble strip show-
ing another test mode to simultaneously dis-
engage the fader group test mode and enter 
the newly selected mode. The encoder switch 
LED for the new choice will light solid while 
the other choices flash.
Touch Test Mode
Touch test mode places the faders in a test mode 
where the scribble strips indicate when a fader 
has been touched and at what frequency the 
fader is currently recognizing. 
When “Tch” Fader Test Mode is Engaged:
• The encoder switch LED located below the 
scribble strip which shows “Tch” will light 
solid indicating that this is the chosen test 
mode.
• All other display test menu items shown on 
the scribble strips as well as their associated 
flashing encoder switch LEDs, will remain vis-
ible in this test mode. The scribble strip dis-
plays will toggle back and forth between the 
fader touch values, as indicated below, which 
allows you to select another display test mode 
without the need to first “Exit” this mode.
• Touch any fader or group of faders to activate 
the test. 
• The fader frequency value will be shown in 
the scribble strips using 3 characters and the 
4th character will always read “k” for “kHz.” 
These values will be updated in real-time as a 
fader is touched.
• Press the flashing encoder switch located be-
low the scribble strip showing another test 
mode to simultaneously disengage the fader 
touch test mode and enter the newly selected 
mode. The encoder switch LED for the new 
choice will light solid while the other choices 
flash.
• When finished, press EXIT.