Digidesign Control 24 Manuale Utente

Pagina di 159
Appendix B: Utility Functions
141
8  
Press the flashing encoder switch below the 
scribble strip showing “Yes” to reset Control|24 
to the default factory settings. 
9  
Control|24’s settings will be reset, the Sys Re-
set menu will be exited and the system will be 
placed in the main UTILITY menu.
You can also press the flashing UTILITY switch 
to exit the UTILITY mode entirely and revert to 
the previous Control|24 operating state.
System Diagnostics
Control|24 will include diagnostics to be run at 
startup, and a separate, comprehensive routine 
involving loop-back. In this way, the customer, 
or Digidesign Customer Service, can confirm 
that a customer’s Control|24 is fully functional. 
Startup Routine/Diagnostics
This power-up start-up diagnostic routine, 
should, at minimum, check fader travel calibra-
tion on each channel. In addition, all internal 
boards should have brief basic “handshake” rou-
tines that check with Control|24’s CPU. 
The following functions will be checked:
• Communication board RAM check.
• Communication board Ethernet connection.
• Establish and check communication to the 
Mac or PC, if turned on.
• Establish and check communication to Pro 
Tools, if launched.
• Check encoder boards.
• Control|24 moves its own faders through 
their travel and reports any non-responding 
faders.
• Once the initial start-up sequence is com-
plete, the Control|24 scribble strips should 
display a message like “Welcome to Con-
trol|24.”
• If communication has been enabled between 
Control|24 and Pro Tools in the Pro Tools Pe-
ripherals dialog, one of two generic messages 
will be displayed on the channel scribble strip 
displays.
• If bi-directional communication has not yet 
been established, or has been disrupted, the 
message will read “Control|24 has gone off 
line and is waiting for Ethernet input.”
• If bi-directional communication has been es-
tablished, the message will read “Open or cre-
ate a Pro Tools session to begin.” This is 
simply a banner message and no switches will 
be active.
• When a session is loading the banner message 
“Pro Tools Session is Loading, Please Wait” 
will be displayed in the scribble strips to alert 
you that something is happening and their 
system has not crashed.