Corporate thermostats
 
 include the Time Guard® II anti-short
cycle protection circuitry. If a non-corporate thermostat without
anti-short cycle protection is used the Time Guard II field in-
stalled anti-short cycle kit is recommended.
 
Refrigerant system 
 
is designed to provide dependability. Liquid
filter dryers are used to promote clean, unrestricted operation.
Each unit leaves the factory with a full refrigerant charge. Refrig-
erant service connections make checking operating pressures
easier.
 
HIGH AND LOW PRESSURE SWITCHES 
 
provide added reli-
ability for the compressor.
 
Evaporator and condenser coils
 
 are computer-designed for
optimum heat transfer and cooling efficiency. The evaporator
coil is fabricated from copper tube and aluminum fins and is lo-
cated inside the unit for protection against damage. The con-
denser coil is internally mounted on the top tier of the unit.
Copper fin coils and pre-coated fin coils are available from the
factory by special order. These coils are recommended in appli-
cations where aluminum fins are likely to be damaged due to
corrosion. They are ideal for seacoast applications.
 
Low sound ratings 
 
ensure a quiet indoor and outdoor environ-
ment with sound ratings as low as 72 dB. (See page 3.)
 
Easy to service cabinets
 
 provide easy single-panel accessibility
to serviceable components during maintenance and installation.
The unit base with integrated drain pan provides easy ground lev-
el installation with or without a mounting pad. Convenient rigging
holds are provided to manipulate the unit on the jobsite. A nesting
feature ensures a positive unit base to roof curb seal when the unit
is roof mounted. A convenient 3/4-in. wide perimeter flange
makes frame mounting on a rooftop easy.
 
Standard metal duct covers
 
 with insulation come with the unit
and cover the horizontal duct openings. These can be left in place
if the units are converted to downflow.
 
Downflow operation
 
 is easily provided in the field to allow ver-
tical ductwork connections. The basepan utilizes knockout style
seals on the bottom openings to ensure a positive seal in the
horizontal airflow mode.
 
Integrated Gas Control (IGC) board 
 
provides safe and efficient
control of heating and simplifies trouble-shooting through its
built-in diagnostic function.
 
Cabinets
 
 are constructed of heavy-duty, phosphated, zinc-
coated prepainted steel capable of withstanding 500 hours in
salt spray. Interior surfaces of the evaporator/heat exchanger
compartment are insulated with cleanable semi-rigid insulation
board, which keeps the conditioned air from being affected by
the outdoor ambient temperature and provides improved indoor
air quality. (Conforms to American Society of Heating, Refriger-
ation and Air Conditioning Engineers No. 62P.) The sloped drain
pan minimizes standing water in the drain, which is provided with
an external drain fitting. 
 
Louvered Grille
 
 provides hail and vandalism protection.
 
574B
N
W
024
040
N
VS
 
  
 
Model Number
 
  
 
574B
 
 – Single 
  Packaged Gas 
  Heating/Electric 
  Cooling
 
Electrical Supply
N
 
 –  208/230-1-60
 
P
 
 –  208/230-3-60
 
Fuel 
W
 
 – Natural Gas
 
P
 
  – Propane Gas
 
Low NO
 
x
 
 Indicator
N
 
 – Low NO
 
x
 
 Unit
Only used if ordering NO
 
x
 
 units
 
Nominal Cooling Capacity
024
 
 – 2 ton
 
030
 
 – 2.5 ton (not yet available)
 
036
 
 – 3 ton
 
042
 
 – 3.5 ton (not yet available)
 
048
 
 – 4 ton
 
060
 
 – 5 ton
 
Heat Input Size
040
 
 –   40,000
 
060
 
 –   60,000
 
090
 
 –   90,000
 
115
 
 – 115,000
 
130
 
 – 130,000
LEGEND
 
CU
 
  — Copper
 
AL
 
— Aluminum
 
Options
BT
 
  –  AL evap, vinyl condens 
 
CC
 
–  AL evap, CU condens 
 
CU
 
–  CU evap & condens 
 
TP
 
–  Base unit with tin plated indoor coil 
hair pins
 
TV
 
–  TP with vinyl coating on outdoor coil 
 
TC
 
–  TP with AL indoor coil and CU/CU 
outdoor coil 
Only used if ordering an option
 
MODEL NUMBER NOMENCLATURE