Condensed Instructions
1. Plug power cord into an appropriate AC 
outlet and let unit warm up for 2 minutes.
2. Check flotation of airflow ball in probe tip.
3. Set Leak Size switch to SM(cal) position.
4. Adjust Balance Control until unit ticks 
slowly (1–3 ticks per second).
5. Place probe tip over Calibrate Reference 
Bottle (remove cap disc from bottle) and 
check for faster audio and flashing lamp.
6. Probe for leaks.
7. For other sensitivity ranges, set Leak 
Size switch and readjust Balance 
Control for 1–3 ticks per second.
WARNING:  This deviceis not to be 
used in any application that is beyond 
its intended purpose or beyond the 
scope of its specifications.   For details 
on appropriate use, refer to the gen-
eral model description, application, and 
operation discussions in this manual.  
Before risking equipment damage or 
personal injury, contact Bacharach if you 
are unsure of the validity of a particular 
combustion analyzer application.
Model Description
  The H-10G Halogen Leak Detector 
consists of a control unit, a probe with 
4-1/2 ft of hose, and an 8 ft power cord, 
all housed in a shock-resistant case.
  The control unit contains a printed cir-
cuit board amplifier, plug-in sensor, air 
pump, power transformer, and speaker 
housed beneath the chassis cover. A 
calibrate reference leak bottle, leak size 
switch, balance control, and power switch 
are located on the top of the control 
chassis. An AC power cord is attached 
on the inside left of the control chassis. A