Braun NUVL603C Manuale Utente

Pagina di 38
Page 17
FUNCTION
POSSIBLE CAUSE
REMEDY
10.00
BARRIER WILL 
NOT OPERATE 
UP OR DOWN 
WITH HAND-
HELD PENDANT 
OR OVERRIDE 
SWITCHES
10.11  Poor plug connections
10.12  Faulty barrier actuator motor or         
           actuator out of adjustment
10.13  Bad power and ground
Check harness connectors A1 and A2, E1, N1, 
N2, E1, F1 and F2.  
Check power at motor.  Adjust or replace actuator 
if necessary.
See 1.00
11.00
BARRIER 
OPERATES WITH 
OVERRIDE 
SWITCH BUT 
WILL NOT GO 
UP WITH HAND-
HELD PENDANT
11.11  Faulty Outer Barrier switch
11.12  Barrier occupied
Check diagnostic LCD for Outer Barrier Switch 
status.  Adjust or replace switch as necessary.
Remove weight from barrier.  See Outer Barrier 
Occupied Calibration on page 5.
12.00
BARRIER 
OPERATES 
WITH OVER-
RIDE SWITCH 
BUT WILL NOT 
GO DOWN WITH 
HAND-HELD 
PENDANT
12.11  Faulty Pressure Transducer
12.12  Stow switch out of adjust-
ment or defective
12.13  Full Out switch out of 
           adjustment or defective
Check Pressure Transducer.  Adjust or replace 
as necessary.  See Ground Sense Calibration on 
page 5.
Check diagnostic LCD for Stow switch status.  
Adjust or replace as necessary.
Check diagnostic LCD for Full Out switch status.  
Adjust or replace as needed.
Troubleshooting Diagnosis Chart
13.00
SWITCHES 
DO NOT 
CHANGE 
STATE IN 
DIAGNOSTIC 
MODE
13.11  No power going to switches
13.12  Faulty wiring
13.13  Faulty connections
Check power on connector A1, pins 1 and 2.
Check continuity of wires from switches to connector 
A2.
Check for proper connections on each switch and 
on each connector on the harnesses.  Replace con-
tact if necessary.  See diagram on following page.
14.00
DOORS 
DO NOT 
OPEN
14.11  Faulty wiring
Check for proper wiring to door openers.
15.00
DOORS 
DO NOT 
CLOSE
15.11  Lift Out switch out of adjustment  
           or defective
Lift not stowed fully.  Adjust lift out switch or 
replace.