Braun NUVL603C Manuale Utente

Pagina di 38
Page 4
Certification Checklist
The following operations and conditions must be functionally verified in order for the lift to be FMVSS 
403/404 compliant.  If an operation does not function as described or a condition is not met, follow the refer-
enced procedures to correct the problem or contact a Braun Corporation Product Support representative.
• Vehicle movement is prevented unless the lift door is closed, ensuring the lift is stowed.
 
 
1.  Verify lift stowed signal (pin 9) in the 9 conductor plug on the side of the pump module has a +12 volt 
signal.
 
2.  Refer to the interlock installation instructions.
• Lift operation shall be inhibited unless the vehicle is stopped and vehicle movement is prevented.
 
 
1.  Verify vehicle secure signal (pin 6) in the 9 conductor plug on the side of the pump module has a +12 
volt signal.
 
2.  Refer to the interlock installation instructions.
• The platform will not fold/stow when occupied.
 
 
- Refer to Platform Sense Calibration.
• The outer barrier will not raise if occupied.
 
- Refer to Outer Barrier Occupied Calibration procedure
• An audio warning (and visual warning for public use lifts) will activate if the threshold area is occupied 
when the platform is a least 1" below floor level. 
 
1.  Make sure connectors to threshold mat are properly connected.
 
2.  Call Product Support.
 
• Lift platform movement shall be interrupted unless the outer barrier is deployed (up).
 
 
 
- Check Barrier Down limit switch, wires and connector.  
 
- Diagnostic LCD should display a value of “1” for OBAR SW when outer barrier is deployed (up).