AD-IS EVERFLOW
 
AIR DRYER OPERATION: 
GENERAL
The  Bendix
®
 AD-IS
®
 EverFlow
®
 assembly alternates 
between the dryers each time the brake system charges. 
During high air demand, the dryers alternate every 30 
seconds  to  allow  drying  of  the  added  volume  of  air. A 
pressure protection valve is needed after the dryers to 
maintain at least 70 PSIG at the dryers during high air 
demand. A Bendix
®
 EverFlow
® 
electronic module monitors 
the air brake system and determines the amount of 
demand.    The AD-IS  EverFlow  assembly  requires  a 
signal from the delivery port of the governor into the 
GOV port of the EverFlow
 
electronic module.  The AD-IS
 
EverFlow assembly also needs a supply air line from the 
secondary tank to the electronic module RES port. 
This 
line must be 3/8 inch, or larger, tubing. 
The AD-IS EverFlow assembly is primarily designed to dry 
air on systems used for bulk unload and central tire inflation. 
The system operates best when a pressure protection valve 
is installed between the EverFlow assembly and the source 
of the high volume air. Refer to the system schematics, 
Figure 2.  This pressure protection valve should have a 
minimum  pressure  of  70  PSIG. 
Delivery pressure in 
excess of 175 PSIG can cause the purge valve to cycle 
rapidly between load and purge mode.
NORMAL BRAKE CYCLE 
(Refer to Figures 3 & 4)
When the compressor is charging (compressing air) air 
flows through the compressor discharge line to the inlet 
(1 IN) port of one of the air dryers. The compressed air 
includes contaminates such as oil, oil vapor, water and 
water vapor. The air then flows into the desiccant cartridge, 
where  it  flows  through  a  liquid  separator  which  collects 
liquids and other contaminants.
COMPRESSOR
GOVERNOR
DESICCANT 
BED
DELIVERY 
CHECK VALVE 
(OPEN)
PRIMARY
PORT (PRI)
PURGE VALVE
(CLOSED)
TURBO 
CUT-OFF 
VALVE
(OPEN)
ENGINE 
TURBO
UNLOADER 
PORT 
SUPPLY 
PORT
PRIMARY
RESERVOIR
PRESSURE 
PROTECTION 
VALVES
AUXILIARY PORTS
(TO ACCESSORIES)
SEE
NOTE 1
Note 1:
The Bendix
®
 AD-IS
® 
air dryer and reservoir 
system purge piston has a purge control 
channel drain. This allows any condensation 
in this area to flow past a diaphragm in the 
top of the purge piston and out through a 
channel in the middle of the central bolt of 
the purge assembly to be drained. During 
the purge cycle this drain is closed.
SAFETY
VALVE
PURGE 
RESERVOIR 
DRAIN VALVE
SECONDARY
RESERVOIR
SECONDARY
PORT (SEC)
PURGE 
RESERVOIR
PURGE 
ORIFICE
OIL COALESCING FILTER 
(BENDIX
®
 AD-IS
®
 PURAGUARD
®
 
OIL COALESCING AIR DRYER)
A
D
C
B
PURGE 
CONTROL 
CHANNEL
FIGURE 3 - 
BENDIX
® 
AD-IS
®
 AIR DRYER AND RESERVOIR SYSTEM CHARGE CYCLE