OPERATION
GENERAL
The AD-RP air dryer alternates between two operational 
modes or “cycles” during operation: the Charge Cycle and 
the Purge Cycle. What follows is a description of operation 
separated into these “cycles”.
CHARGE CYCLE 
(Refer to Figure 3.)
When  the  compressor  is  loaded  (compressing  air) 
compressed air — along with oil, oil vapor, water and water 
vapor — fl ows through the compressor discharge line to the 
supply port of the air dryer body.  Air entering the supply 
port immediately encounters the “turbo cut-off” valve. With 
no air pressure in the control port, the turbo cut-off piston 
moves the valve away from its seat in the body, allowing 
the supply air to enter the body. As air travels through the 
end cover assembly, its direction of fl ow changes several 
times,  reducing  the  temperature,  causing  contaminants 
to condense and drop to the bottom (or sump) of the air 
dryer body. After exiting the end cover, the air fl ows into the 
desiccant cartridge where an oil separator — or coalescing 
fi lter, if equipped with a Bendix
®
 PuraGuard
®
 oil coalescing 
The  aluminum  body  of  the  Bendix
® 
AD-RP
  air  dryer 
contains  the  following  serviceable  components  or 
assemblies: the turbocharger cut-off valve; the heater and 
thermostat  assembly;  a  delivery  check  valve  assembly; 
and  the  combined  purge  and  relief  valve  assembly. All 
service  and  replacement  can  be  accomplished  from  the 
exterior of the dryer without removing it from the vehicle. 
The spin-on desiccant cartridge is removed and installed 
using a “strap wrench.”
The  AD-RP  air  dryer  has  four  female  pipe  thread  air 
connections identifi ed as follows: (Also refer to Figure 1.)
Air Connection Port ID Function/Connection
CON 4 
Control Port (purge valve control 
& turbo cut-off)
SUP 1
Supply Port (air in)
DEL 2 
Delivery Port (air out)
PT 22 
(not identifi ed on 
the air dryer)
Remote Purge Port
DESICCANT 
DELIVERY 
CHECK 
VALVE
DELIVERY
PORT
TURBO 
CUT-OFF 
CONTROL 
PORT 
GOVERNOR
COMPRESSOR
PURGE 
VALVE
FRONT
RESERVOIR
REAR
RESERVOIR
ENGINE 
TURBO
EXHAUST
PORT
SUPPLY 
PORT
OIL 
COALESCING 
FILTER
PURGE 
ORIFICE
SAFETY 
VALVE
REMOTE 
PURGE 
PORT
REMOTE 
PURGE 
RESERVOIR
PURGE 
CONTROL LINE
FIGURE 3 - BENDIX
®
 AD-RP
 AIR DRYER SYSTEM - CHARGE CYCLE