Brother Z-8550A Manuale Proprietario

Pagina di 128
 
 
Z-8550A, 8560A 
12. TREADLE UNIT 
105 
12-3. Standard settings for treadle depression stroke 
 DANGER 
 
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet 
before opening the cover of the control box. Touching areas where high voltages are present can result in severe 
injury. 
Carry out the following reset procedure if the specifications for the treadle unit have been changed or if the treadle unit or 
main P.C. board has been replaced. 
The following procedure sets the operating positions for the treadle depression strokes to the standard values.
 
 
1) Entering signal settings 
1.  Set the power switch (1) to OFF. 
2.  Set DIP switch No 4 to “ON”. 
 
 
 
 
 
 
 
 
 
 
3. While pressing the straight stitch key (2), turn on the 
power switch (1). 
“PdFF x.xxx” will appear in the main display (3). 
(x.xxx indicates the depression voltage.) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2) Storing the maximum forward depression amount 
Press the straight stitch key (2) while the treadle is at the 
point of maximum forward depression. 
“Pdnn x.xxx” will appear in the main display (3). 
 
 
 
 
 
 
 
 
 
 
3572M
3573M
3574M