Brother Z-8550A Manuale Proprietario

Pagina di 128
 
 
Z-8550A, 8560A 
3. FUNCTION SETTINGS
4
3-2. List of memory switch settings 
Memory switch No. 0 - 15 
No. 
Initial value 
Setting range 
Setting details 
0 0 
(degrees) 
-10 - 10 
(degrees) 
Needle up stop position setting 
 
 
 Higher 
Lower 
 
1 0 
(degrees) 
-10 - 10 
(degrees) 
Needle down stop position setting 
 
 
 Higher 
Lower  
 
0 - 1 
Depressing treadle forward when treadle is depressed backward (thread 
trimming) 
0: Disabled (Enabled after treadle is returned to neutral position and then 
depressed forward) 
1: Enabled 
0 - 1 
Power supply voltage drop check (reset detection) function   
0: None 
1: Enabled, [Err 95] displayed when voltage drops. 
0 - 1 
Buzzer (electronic sound) during panel operation 
0: Yes 
1: None   
5 0 
[Do not change this setting.] 
0 - 1 
Piercing force boosting operation 
0: Yes 
1: None 
0 - 1 
End backtacking speed 
0: Limited by speed bar key setting 
1: Not limited by speed bar key setting 
0 - 1 
End backtacking sewing speed 
0: Speed can be set independently from start backtacking speed 
1: Speed is set to start backtacking speed 
12 
0 - 1 
Presser foot condition when treadle is returned to neutral position after 
thread trimming 
0: Presser foot is lowered (it is not lowered when DIP switch 1 is OFF) 
1: Presser foot is not lowered 
13 
0 - 1 
Presser foot condition when operation stops at the neutral treadle position 
0: Presser foot is not lifted 
1: Presser foot is lifted 
14 
0 - 1 
Actuator function 
0: Operates as a reverse stitch switch during sewing, and as a correction 
stitch switch when sewing is stopped 
1: Thread trimming switch 
15 
0 - 1 
Deceleration stop control when treadle is returned to neutral position 
0: Deceleration stop control without single stitch advance 
1: Above control is not carried out 
0212B
0212B