Pagina di 36
System status LEDs
3
10
Brocade Mobility RFS6000 Controller Installation Guide
53-1001573-03
Fan LED
Temperature status LED
Fan LED
Event
Off
System Off / POST Start
Green Blinking
POST in Process
Green Solid
All System Fans Normal Operation
Amber Solid
Redundant Cooling Failure 
System Operational
Amber Blinking
System Cooling Failure
System will be held in reset until the issue is 
resolved
Temperature LED
Event
Off
System Off 
Green Solid
Ambient Inlet Temperature is within specified 
operating limit
Amber Solid
Ambient Inlet Temperature is near the maximum 
operating temperature

During controller start up this LED will be lit 
Solid Amber. This is normal behavior and does 
not indicate an error.
Amber Blinking
Ambient Inlet Temperature is above the 
maximum specified operating temperature
System will be held in reset until the issue is 