Cleaning 3 
 
Clean the EZ Melt after every use.  Follow these 
steps: 
1.  Turn on the heat and the pump. 
2.  Press the foot pedal to pump shortening out 
of the EZ Melt and into a metal container or 
fryer kettle. 
3.  When you cannot pump any more shortening 
out of the EZ Melt, release the foot pedal.  
Turn off the heat and the pump. 
4.  Disconnect the EZ Melt from the power 
source. 
5.  Allow the shortening in the EZ Melt kettle 
to cool to 115
“ F/46“ C. 
WARNING 
Hot shortening can cause serious injury. 
6.  Clean the EZ Melt filter.  Follow these steps: 
a.  Allow the filter assembly to cool to the 
touch. 
b.  Lift off the filter assembly, holding it by 
the frame. 
c.  Invert the filter assembly over a sink or 
garbage can and shake the sediment off 
of it. 
d.  Unsnap the filter to remove it from the 
filter frame. 
e.  Rinse the remaining shortening and 
crumbs off of the filter. 
WARNING 
Thoroughly clean and dry the floor if 
shortening, water, or other materials are 
spilled.  Materials spilled on the floor may 
cause serious injury and loss of life. 
7.  Remove the cube melter. 
8.  Loosen the two fasteners at the back of the 
heater head, lift it off the kettle and place it 
in a clean safe place. The foot valve and 
cord will unsnap from the frame.  See Figure 
3-1. 
Figure 3-1.  Removing the Heater Head. 
(Place heater head as shown above so no 
damage is done to the element.) 
Belshaw Bros., Inc. 
š 1750 22
nd
 Ave. S. 
š Seattle, WA 98144 š Phone 206-322-5474 š Fax 206-322-
5425 
10 
MN-1316EN 
EZ Melt Model EZ18, EZ24, EZ34