Beckett AQUASMART 7600 Manuale Utente

Pagina di 36
4
Figure 2 - Basic Dimensions (inches)
Mounting
OEM Installation: When replacing an OEM-installed 
AquaSmart, consult the appliance manufacturer’s wiring 
diagrams and instructions for additional information.
Retrofi t Installation:  The AquaSmart can be used to 
replace most standard boiler temperature controls. For a 
cross-reference of compatible replacements, refer to 
Table 1
There are two basic methods for mounting the 
AquaSmart to the boiler as outlined in Figure 3.
Sensor/Immersion Well Mounting – This is the 
most common method.  If the existing well is not 
suitable for any reason, a standard design 
aftermarket immersion well with the proper 
dimensions can be purchased from a HVAC 
distributor.  The AquaSmart can then be mounted in 
the typical way.
Surface Mounting – This is sometimes required 
and is part of the AquaSmart base design.  The 
base has adequate clearance built-in to 
accommodate the temperature sensor lead exiting 
the back of the control.  A remote mounting kit (Pt. 
No. 7600RMU) that includes a 48” extension cable 
and mounting screws can be purchased separately 
for applications where needed.
1.
2.
Installation
Figure 3 - Mounting Options
Surface Mounting:
Sensor/Immersion Well Mounting:
Position the strain relief over the hex,
capturing the sensor cable and crimp to secure.
4.92
4.50
3.51
3.04
5.38
.75
3.50
SK10013
6.50
Sensor Lead
 (a 48” 
extension cable can be 
purchased separately)