Bay Technical Associates BayTech DS72 Manuale Utente
DS72 HOST MODULE OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
8
DETAILED OPERATION AND CONFIGURATION
The following section, “Detailed Operation and Configuration,” provides a detailed approach to
accessing, operating, and configuring the DS72 network interface module.
accessing, operating, and configuring the DS72 network interface module.
NOTE: It is important that you type all commands correctly. Any combination of wrong
entries results in an error message.
entries results in an error message.
ACCESSING MAIN Apply power to the module. The following header and main menu appear:
MENU
MENU
Data Switch Series - F.1.00
Bay Technical Associates
Unit ID: BAYTECH DS72
Bay Technical Associates
Unit ID: BAYTECH DS72
Port Select Code: $BT
Attention Character: ;
Device A (2,1)...........1
Device B (2,2)...........2
Device C (2,3)...........3
Device D (2,4)...........4
DS-RPC (3,1)...........5
Configure.......................C
Status..........................S
I/O Modules Reset...............RM
Unit Reset......................RU
Exit............................X
Logout..........................T
Attention Character: ;
Device A (2,1)...........1
Device B (2,2)...........2
Device C (2,3)...........3
Device D (2,4)...........4
DS-RPC (3,1)...........5
Configure.......................C
Status..........................S
I/O Modules Reset...............RM
Unit Reset......................RU
Exit............................X
Logout..........................T
Enter Request :
NOTE: Depending on the DS-Series model, the menus may vary according to the number of
DS74 modules installed in the unit.
DS74 modules installed in the unit.
If this is not an initial set-up and Password has already been enabled, you
are prompted to login. After logging in successfully, the main menu will
appear.
are prompted to login. After logging in successfully, the main menu will
appear.
NOTE: Password feature is case sensitive.
SELECTING A DEVICE There are two methods of selecting a device, menu driven selection and
ASCII character string method.
Menu Driven From the main menu, select the number that corresponds to the device you
Selection
Selection
wish to access, followed by <cr>. To return to the main menu, send the
attention character five times (;;;;;).
attention character five times (;;;;;).
ASCII Character Another method of selecting devices and operating the DS-Series and DS
String
String
RPC is the ASCII character string method. To select a device located on
a peripheral Port, type $BTm,p where m is the module and p is the port.
To configure a module, type $BT and the module number followed by
a peripheral Port, type $BTm,p where m is the module and p is the port.
To configure a module, type $BT and the module number followed by