Data Acquisition Connections 
 
 
The connections to the Data Acquisition Module are made 
through a DB-25 (male) connector.  The FBDA is pin compatible with 
B&B Electronics’ SDAXX, and ADIO12 modules.  This allows you to 
simply plug the FBDA into one of the above data acquisition 
modules, and the data acquisition module connections to the FBDA 
are complete.  Table 2.2 contains the DB-25 (male) pin 
assignments. 
 
1.   ------- denotes no connection. 
2.   The conditioned sensor signal is available on pin #8 and is 
labeled Vout. 
3.   Pin #9 is connected straight through to terminal block A/D 1 (no 
signal conditioning circuitry). 
4.   Pins #17 and #18 are looped to each other to provide +5V to 
REF+ in the SDAXX line of A/D modules. 
5.   Pin #19 provides 0V to REF- in the SDAXX line of A/D modules. 
 
 
Figure 2.1 contains a diagram of the connections required to read 
the signal produced by a sensor. 
Table 2.2: DB-25 (Male) Pin Assignments 
DB-25 Pin # 
Function 
DB-25 Pin # 
Function 
1 GND  14  ------- 
2 -------  15  ------- 
3 -------  16  ------- 
------- 
17 
looped to 18 
------- 
18 
looped to 17 
6 -------  19  GND 
7 GND  20  ------- 
8 Vout  21  ------- 
9 A/D 
1  22  ------- 
10 -------  23 
------- 
11 -------  24 
------- 
12 -------  25 
------- 
13 -------