CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
 
 
13
 
 
Configuration Commands 
Configuration commands allow changing of the unit's setup parameters without the Use 
of a menu. They may be used on serial or parallel units. To enable processing of 
configuration commands, depress both of the unit's front panel switches. The MODE 
and BUSY LEDs will light. This indicates that the unit is in configuration mode. The unit 
must be in this mode to process configuration commands. To leave the configuration 
mode, depress both switches again. The MODE and BUSY LEDs will return to the state 
they were in prior to entering configuration mode. While in configuration mode, but not in 
the menu, the DATA LED will flicker in response to data received on port 1. 
Entering configuration mode will stop data transfer to the shared device, and also erase 
all data in the buffer. No new data can be loaded into the unit while in configuration 
mode. Configuration commands are recognized when input to PORT 1 ONLY. If a 
configuration command contains any syntax or value errors, it is ignored. A valid 
command is processed immediately upon receipt of the last character of the command 
and does not require a carriage return or line feed terminator. With serial units, carriage 
return is an illegal character in a configuration command, as it will cause entry into the 
configuration menu. 
 
Table 2. Configuration Commands 
Command 
Syntax 
Comments 
Serial Protocol  
!@FPabcd 
See table 3 for full syntax 
Parallel Protocol 
!@FPabcd 
See table 4 for full syntax 
Timeout 
!@Txxx  xxx=002 to 255  Leading zeroes required 
Initialization string 
!@Ixxxxxxxx 
See explanation for                              
syntax 
Formfeed enable 
!@NY 
 
Formfeed disable 
!@NN 
 
Keep command 
!@K 
Must be used to save 
Filler characters 
!@Cxxx  xxx=000 to 255  Leading zeroes required 
Unidirectional XON/XOFF 
enable 
!@UY 
 
Unidirectional XON/XOFF 
disable 
!@UN 
 
Reverse data timeout 
enable 
!@RY 
 
Reverse data timeout 
disable 
!@RN 
 
Timeout on busy enable 
!@BY 
 
Timeout on bust disable 
!@BN 
 
Parallel enable logic 
enable 
!@PY 
 
Parallel enable logic 
disable 
!@PN 
 
Operator switch disable 
!@L