Rose electronic Photo CTP-8S Manuale Utente

Pagina di 40
 
22 
CARETAKER PLUS INSTALLATION AND OPERATIONS MANUAL
 
 
 
Flow Control Display Mode (Serial Models Only) 
By pressing the ADVANCE switch during normal operation, the LED display is 
switched to the flow control display mode. The MODE LED illuminates to indicate this 
mode is active. You may return to normal display mode by pressing the ADVANCE 
switch again. During flow control display mode, the corresponding port LEDs light only 
when the Caretaker Plus has instructed the connected device to stop sending data via 
the port's currently selected protocol. Thus, an input device should not be transmitting 
data to the Caretaker Plus when its LED is lit. The only time Caretaker Plus instructs a 
device to stop sending data is when the device's buffer is full. Thus this display may be 
used to monitor buffer status. Also, in this mode the BUSY LED reflects the flow control 
status of the shared device's input buffer.