Telus Modem IR1200 Manuale Utente

Pagina di 54
 
iR1200 Modem 
43 
 
TROUBLESHOOTING 
This chapter describes typical configuration problems and provides instructions on how to troubleshoot issues with the iR1200 
modem.  
Common Problems 
Page 43 
Error Messages 
Page 44 
Diagnostic Commands 
Extended AT Command 
Extended Error Result Codes 
Page 45 
Page 45 
Page 45 
Common Problems 
The following table identifies the most common problems that may occur while setting up and using your modem for data calls. 
!
 
IMPORTANT INFORMATION: Customers cannot ping a Non Routable IP address 
when provisioned due to the NAT (Network Address Translator) Server.  This server 
attaches a Class C Public IP Address to a Private Class A Non Routable IP address 
for a specific period of time to browse the public internet. This Class C address is 
needed in order to route on the public internet, as Non-Routable IPs are for internal 
routing only (Intranet). 
 
Symptom 
Troubleshooting Tips 
The modem does not respond 
to AT commands. 
Make sure that: 
 
The modem is powered on. 
 
The cable is properly connected to the modem. 
 
The cable is connected to the correct port. 
 
The correct port is specified in your communication software. 
 
The modem is set to the same baud rate specified in the communication software. 
The NO CARRIER message 
displays when the modem 
attempts data calls. 
Make sure that the S7 register contains a value greater than or equal to 60 by issuing an AT&V 
command or by explicitly setting ATS7=’x’ (where x is, enter any number between 1 and 255). 
Modem does not auto-answer 
incoming data calls (not 
default operation). 
Make sure that the S0 register contains a value other than 0 (zero) by issuing the AT&V 
command. You can also explicitly set ATS0=x from the software’s command mode (where x is 
any number between 1 and 255). 
Received data is 
unrecognizable. 
Make sure that the flow control is set to RTS/CTS (hardware flow control is enabled) in the 
communication software and is set to &K3.  
Data is being intermittently 
lost. 
Make sure that the flow control is set to RTS/CTS (hardware flow control is enabled) in the 
communication software and is set to &K3. 
Modem seems to respond 
slower than usual. 
Check the signal strength icon to be sure the signal is not weak. 
Modem keeps dropping 
connection. 
Check the signal strength and signal quality icon to be sure the signal is not weak or poor.