Home Automation HAI (Home Automation Inc.) Home Security System 20A00-1 Manuale Utente

Pagina di 68
 
Page 14 
 
 
 
SOUNDER OUTPUTS 
 
The Horn Output provides 12VDC to power bells, piezo sirens, self-contained sirens, and siren drivers (do not connect speakers 
to the Horn Output).  Sounders can draw up to 1 amp MAXIMUM, split between the Interior and Exterior Horn Outputs  - (See 
Specifications for UL Ratings).  Use a relay connected to an auxiliary power supply if higher current draw is required. 
 
INTERIOR SOUNDER HOOKUP 
 
1.  Locate the interior sounder in a central location.  The sounder is very loud.  Do not install it in a room where small children 
or animals could be trapped if the alarm is activated. 
 
2.  The Interior Horn Output monitors the wiring to bells and sirens.  When enabled, it will report trouble and make a digital dial 
out when an open, short, or other wiring problem is detected in the supervised bell circuit.  When violated, the following 
trouble is displayed on the console, "FIRE TAMPER TRBL NOW". 
 
3.  For UL Listed residential fire alarm applications, the UL Listed Wheelock Model MT-12/24-R Multitone Signal or 
equivalent must be used, and the "SUPERVISE INT SNDR" feature must be set to "ON". 
 
4.  Refer to FIGURE 7 (SOUNDER CONNECTION) for connections. 
 
EXTERIOR SOUNDER HOOKUP 
 
1.  If used, wire tamper switches to a tamper zone with a 1000-ohm end-of-line resistor. 
 
2.  The Exterior Horn Output monitors the wiring to bells and sirens.  When enabled, it will report trouble and make a digital 
dial out when an open, short, or other wiring problem is detected in the supervised bell circuit.  When violated, the following 
trouble is displayed on the console, "FIRE TAMPER TRBL NOW". 
 
3.  To enable supervision of the Exterior Horn Output, the "SUPERVISE EXT SNDR" feature must be set to "ON". 
 
4.  Refer to FIGURE 7 (SOUNDER CONNECTION) for connections.