REPORT OPEN/CLOSE 
 
The communicator can be setup to send an opening and a closing report by user code.  Whenever the system is disarmed the 
communicator will send an opening report to the central station.  When the system is armed, the communicator will send a closing 
report to the central station. 
 
 
 
 
REPORT OPEN/CLOSE:     0 
 
 
 
0=NO 1=YES             
 
 
To enable the communicator to send opening and closing reports to the central station, select the 1 (YES) key. 
 
AUTOMATIC TEST TIME 
 
The communicator CAN be setup to automatically send a test code to the central station on a periodic basis.  AUTOMATIC 
TEST TIME is used to set the time and days of the week of the test, and the TEST CODE specifies the code that will be 
transmitted for the test. 
 
   AUTOMATIC 
TEST 
TIME: 
 
 
 
 
 
   --     NEVER  #=CHNG
 
 
To disable the automatic test, press the ' # ' key and then 0 for Never, and ' # '.
 
 
 
 
 
TEST CODE:          98
 
 
 
 
0-FF                   
 
 
ALARM CODES (4/2 and 3/1 Formats) 
 
Press the down arrow (") to advance to the next ZONE ALARM CODE.  Press the up arrow (!) to go to the previous ZONE 
ALARM CODE.  To change an alarm code, enter two digits for 4/2 format, or one digit when using 3/1 format, then press the ' # ' 
key. 
 
Enter the 2 digit alarm code (1 digits if using 3/1 format) and press ' # '.  To enter the digits B-F, first press the OFF key, then 
press the 1-5 key respectively (i.e. B1 = OFF 1 1 # and CB = OFF 2 OFF 1 #).
 
 
The various alarm codes are sent when the indicated alarm zone is tripped.  Each alarm code must be two digits long for 4/2 
format (01-FF), 1 digit for 3/1 format (1-F). 
 
To disable the digital communicator for a specific zone, set the alarm code to 0 or 00.  The digital dialer will  
not report when this zone is tripped. 
 
 
 
 
ZONE 1 ALARM CODE:  01 
 
 
 
0-FF                   
 
 
THROUGH 
 
 
 
 
USER 16 CLOSE CODE: 76 
 
 
 
0-FF