f6-20.wmf
Figure 6-20. Option -09 Service Position
If the signal at the input to U801A (pin 5) is incorrect, U804 may be defective, or the
switch codes may be wrong. If the latter problem is suspected, refer to Table 6-28 and
test the control lines to U804 (U804-1, 8, 9, 16). If a logic error is found, it may be due to
excessive loading or a faulty data latch (U803), or other cabling or main-board digital
problems. High-frequency oscillation problems are usually caused by switches being on
when they should be off, resulting in positive feedback loops being closed around
portions of the scaling circuitry.
Table 6-27. AC Signal Tracing
RANGE
INPUT VOLTAGE (1
kHz)
VOLTAGE AT TP801
VOLTAGE AT TP802
200 mV
100 mV
20 mV
1 V
2V
1V
200 mV
1 V
20V
10V
2V
1V
200V
10V
20 mV
100 mV
700V
100V
200 mV
100 mV
If the signal at TP802 is incorrect, but U801-5 is OK, the digitally controlled filter section