APC AP9810 Manuale Utente

Pagina di 4
Dry Contact I/O Accessory (AP9810) Technical Guide
Overview
The APC
®
 Dry Contact I/O Accessory provides a hardware interface for connecting the host device 
of a Network Management Card 2 (AP9631 or AP9635) with peripheral devices. The Dry Contact 
I/O Accessory includes:
•  Inputs (
labeled
 Zones A and B) for two dry contact devices
•  One 12 V, 25 mA power output (labeled Pwr)
•  One Form C relay (relay outputs labeled Output).
Dry Contact I/O Accessories connect to Universal I/O ports on your Management Card 2: AP9635 
includes one port and AP9631 includes two ports. Through your Management Card 2 software 
interface, you specify which alarms will cause a change in the state of the Form C relay. You also set 
the actions that will occur at the host due to a change in state of your dry contact devices.
Installation
Install the Dry Contact I/O Accessory using the details below. Connect devices to the screw terminal 
block using the following subsections. 
Note: The Management Card 2 must have application firmware v5.0.2 or greater. For 
details on upgrading the Management Card 2 firmware, see the user’s guide on the 
Network Management Card Utility CD or on the APC Web site (www.apc.com).
Note: If you are using PowerChute Network Shutdown (PCNS) and if your Management 
Card 2 has two Universal I/O ports, you must connect the Dry Contact I/O Accessory to 
Universal I/O port 2. PCNS supports only one Dry Contact I/O Accessory.
Item
Description
Screw terminal block; accepts 16 AWG to 28 AWG wires
Dry Contact I/O Accessory
25.4 cm (1 ft) CAT-5E RJ-45 patch cable used to connect the Dry Contact I/O 
Accessory to a Universal I/O port on a Management Card 2
dm
p0
1
1
4
a
Zone
Pwr
Output
B
A
NO
COM
NC
GND +1
2 NC
COM
NO
COM N
C