VIZIO EXES-5000 CPU-55 Manuale Utente

Pagina di 32
General Purpose Control
Station  may  be  restricted from access to this function. This
function can control other  equipments by employing the
Data Transmitting and  Receiving  Units.
Select the required type of output.
(Mode 1)  One-shot make output
Dial
(000 ~ 499,  max.  of 500 contacts)
and the relay output is made for 1  to 2 seconds.
Example: Door 
remote 
and 
VTR 
control
Note: 
Operation performed even when all  link cir-
cuits are occupied.
(Mode  2)  Make/break  output
Dial
(000 ~ 511, max. of 512 contacts)
and the make output is sent out.
Dial
(000-511,  max. of 512 contacts)
and the break output is sent out.
(Mode 3)  8 selectable  make output and/or decimal output
(A) Unit block number (max. 9)
Dial
and one of the 8 relay outputs is made, and 
the
condition is indicated numerically. Select the-
required output type.
(B) Unit block number (max. of 64 (99))
Dial
( X
2
 and X
2
 are unit No., Y
2
 is condition No.)
and  one of the 8 relay outputs is made, and the
condition is indicated numerically. Select the
required output type.
Example:  Destination indication, room condition indi-
cation, ITV control
(Mode 4)  4 decimal digits output
Dial
and 4 decimal  digits are indicated.
8 selectable output type indication panel
Decimal output type indication panel
4 decimal digits
Control with one-shot make output
Lamp on/off indication panel
X is unit No. (1~9),
Y Y Y Y is 4 decimal
digits (0000~9999)
(X
1
 is unit No., Y
1
 is condition No.)
— 29 —