where <parameter pair> is   
<parameter>=<value>\r\n 
[<parameter pair>] 
Only the parameters that you set and readable will be returned. 
 
Example: Set the IP address of server to 192.168.0.123 
Request: 
http://myserver/cgi-bin/admin/setparam.cgi?Network_IPAddress=192.168.0.123
 
 
Response: 
HTTP/1.0 200 OK\r\n 
Content-Type: text/html\r\n 
Context-Length: 33\r\n 
\r\n 
network.ipaddress=192.168.0.123\r\n 
 
Available parameters on the server 
The follow is the list of the security level of parameters. 
Security level 
SECURITY 
LEVEL 
SUB-DIRECTORY 
DESCRIPTION 
0  
anonymous 
Unprotected. 
1 [view] 
anonymous,  viewer, 
dido, camctrl 
1. Can view, listen, talk to camera 
2. Can control dido, ptz of camera 
4 [operator] 
anonymous,  viewer, 
dido, camctrl, 
operator 
Operator’s access right can modify most of 
camera’s parameters except some privilege and 
network options 
6 [admin] 
anonymous,  viewer, 
dido, camctrl, 
operator, admin 
Administrator’s access right can fully control the 
camera’s operation. 
7  
N/A 
Internal parameters. Unable to be changed by