XS Scuba Buoyancy Compensator Manuale Utente

Pagina di 24
BC Owner’s Manual      19
.
   
XS Scuba, Inc
NOTE: Depressing the oral inflator while the BC is empty may allow 
water to enter the air cell.
Venting With the REV 
   Inside the power inflator’s corrugated hose is a cable that attaches the power 
inflator to the rapid exhaust valve at the top of the airway assembly.  You can 
thus vent air from the BC by pulling straight down on the power inflator. 
   The amount of air vented depends on how far open the exhaust valve is (i.e., 
the distance you pull the inner cable) and how long it is open.  Short pulls vent 
small amounts of air for minor changes in buoyancy, and a long pull will vent 
the entire BC in a matter of seconds.  
   You retain just as much control over your buoyancy using the Rapid Exhaust 
Valve as with the oral inflator button.  You also get the benefit of eliminating 
water entry even if the exhaust valve remains open after release of all the air.  
This valve provides an effective and convenient way to vent air from the BC 
while you are in either an upright or face-down swimming position, and is more 
convenient to use than the oral inflator. 
Rear Dump Valve – If your BC has a Rear Dump Valve located on the lower rear 
portion of the air cell, it can be opened manually to quickly dump air by pulling 
on the ball and cord assembly. This valve works best while making a head-first 
descent, or in a face-down swimming position.
CAUTION:  The  proper  function  of  the  overpressure  relief  valve  is 
essential to prevent damage to the BC air cell.  Unauthorized service 
or tampering may render this valve inoperable, and could cause the air 
cell to leak or burst.  This type of damage is not repairable, and is not 
covered under the terms and conditions of the XS Scuba Warranty. 
NOTE:  Most  training  agencies  recommend  that  you  should  descend 
in  an  upright,  feet-first  position,  in  order  to  maintain  a  slower  and 
more  controlled  descent.    This  is  especially  true  if  you  experience 
difficulty equalizing your ears, or if you are descending in low visibility 
conditions.
Right Shoulder OPV / Dump Valve (not featured on all models) 
Some models may feature a redundant OPV/Dump valve, located 
at  the  top  of  the  right  shoulder.    A  ball  and  cord  assembly 
extends  to  the  shoulder  buckle  assembly  for  quick  dumping 
of air.