Siemens TV Converter Box 611 Manuale Utente
Technical data and characteristics
14.2 Data sheets and diagrams
Data sheet 1FW6290-xxB11-xxxx
Table 14- 41 1FW6290-xxB11-7Axx, 1FW6290-xxB11-0Lxx, 1FW6290-xxB11-2Pxx
Technical data
1FW6290
1FW6290
Symbol
Unit
-xxB11-7Axx -xxB11-0Lxx -xxB11-2Pxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
35
Rated temperature of winding
T
N
°C
130
130
130
Rated data
Rated torque
M
N
Nm
3320
3200
3100
Rated current
I
N
A
59
91
110
Maximum speed at rated torque
n
MAX,MN
rpm
73
130
170
Rated power dissipation
P
V,N
kW
7.13
7.14
7.16
Limit data
Maximum torque
M
MAX
Nm
6280
6280
6280
Maximum current
I
MAX
A
130
210
270
Electric power of motor at M
MAX
P
EL,MAX
kW
58
78.2
93.2
Maximum speed at maximum torque
n
MAX,MMAX
rpm
40
71
93
No-load speed
n
MAX,0
rpm
110
180
230
Torque at n = 1 [rpm]
M
0
Nm
3490
3490
3490
Current at M
0
and n = 1 [rpm]
I
0
A
62
100
120
Thermal static torque
M
0
*
Nm
2470
2470
2470
Thermal stall current
I
0
*
A
44
70
90
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
56.1
35.1
27.4
Voltage constant
k
E
V/(1000/min)
3393
2124
1655
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
41.9
41.8
41.8
Thermal time constant
t
TH
s
180
180
180
No. of pole pairs
p
-
42
42
42
Cogging torque
M
COG
Nm
17
17
17
Stator mass
m
S
kg
114
114
119.2
Rotor mass
m
L
kg
45
45
45
Rotor moment of inertia
J
L
10
-2
kgm
2
334
334
334
Phase resistance of winding at 20 °C
R
STR, 20
Ω
0.43
0.169
0.103
Phase inductance of winding
L
STR
mH
8
3.1
1.9
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
5.35
5.36
5.38
Recommended minimum volume flow
H,MIN
l/min
8.6
8.6
8.6
Temperature increase of the coolant
ΔT
H
K
9
9
9
Pressure drop
Δp
H
bar
0.8
0.8
0.8
1FW6 Built-in torque motors
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7
293