Rinnai Corporation EX08C, EX11C Manual 
 
 EX08C 
EX11C 
Application 
For manufactured home (USA only) or mobile home or residential installation 
convertible for use with natural gas and liquefied petroleum gases (propane / LPG) 
when provision is made for the simple conversion from one gas type to the other. 
For commercial setting. 
For installation at altitudes up to 10,200 feet (3109 m).  
General Description 
Forced combustion, forced convection, flued gas furnace  
Operation 
Push button electronic  
Gas Connection 
1/2 in male NPT   
Gas Control 
Electronic  
Burners 
Stainless steel Bunsen burner  
Temperature Control 
Electronic thermostat, (Low, 60-80ºF in 2ºF increments, High) 
Ignition System 
Electronic spark ignition  
Flue System 
The flue must be terminated to atmosphere with only flue components listed with the 
appliance’s certification.  Warranty will be voided if non listed components are 
installed.  
Humidifier Tray 
Capacity - 1.5 pints (700 cc)   
Electrical Connection 
AC 120V, 60 Hz, 41 watts  
AC 120V, 60 Hz, 44 watts  
Standby Power 
0.5 watt   
Weight 
Noise Level 
27-36 dB 
31-38 dB 
AFUE Rating 
Natural Gas: 81%           
Propane: 82% 
Natural Gas: 80%           
Propane: 81% 
46 lbs (21 kg) 
Specifications 
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without 
prior notice. 
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating 
conditions and was determined independently of any installed system. 
  Safety Features 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
•  Overheat:  The appliance will automatically shut 
down when the appliance exceeds a predetermined 
temperature. 
•  Flame Failure:  The appliance will automatically 
shut down if the burner flame is extinguished. 
•  Power Failure:  The appliance will shut off the gas 
if it loses electrical power. 
•  Power Surge Fuse:  A glass fuse on the PC board 
protects against overcurrent.  If the fuse blows then 
all indicator lamps will be off. 
•  Spark Detector:  The appliance automatically shuts 
down if there is an abnormal spark at ignition. 
•  Fusible Link:  In case the overheat feature does 
not prevent an overheat then the fusible link could 
break, shutting off the appliance. 