Chapter 3: Communication Setup
ISACC RS232 SPECIFICATIONS
Start/Stop protocol:  XON/XOFF only
Communications protocol:  8 data bits, no parity, 1 stop bit
DB25 socket configuration:  DCE female
RS232 receptacle configuration (refer to diagram below):
Pin 2 = Received Data (Receive)
Pin 3 = Transmitted Data (Send)
Pin 6 = DSR (Data Set Ready)
Pin 7 = Ground
13
12
11
10
9
8
7
6
2
3
4
5
1
25
24
23
22
21
20
19
18
17
16
15
14
ISACC's RS232 DB25 Socket
NETWORK WIRING
ISACC units may be connected in a network using as few as two units and as many as 16
units.  The units are connected together using 2 conductor twisted pair cable (Belden 9841 or
equivalent) to the networking terminal block (also called a port) labelled RS485.  The 2-
position RS485 terminal block is positioned next to the RJ11 phone jack on the circuit board.
See below:
PHONE
A
B
RS485
P9
OFF
ON