Tektronix Camcorder 2200 Manuale Utente

Pagina di 316
2-102
Section 2— Control Panel Descriptions
Rear Panel Switches 
The rear panel includes a number of switches that control 
operating modes, such as address, bus enable, delegate enable, 
and test mode. These switches are set up during installation, as 
described in the Installation section of the Model 2200 Installation 
and Service
 Manual.
Remote Aux Operation 
Operation of the Remote Aux Panel is identical to operation of the 
local aux panel installed in the switcher control panel. 
If the switcher setup identifies a bus pair (that is 2A and 2B) as 
video and key, selecting a source on bus 2A will also change 2B. 
To split the key selection will require use of the 3-RU panel or two 
of the 1-RU or 2-RU panels (one set up for each bus). 
More than one Remote Aux Control Panel can attempt to control 
a single aux bus. When two or more panels controlling the same 
bus have source buttons pressed, the panel with the highest 
address will control the source. 
Chop 
The chop function switches rapidly between two inputs; this is a 
test function and not a creative feature. To start the chop function, 
press the first input button then double press the second input 
button. to stop the chop button press any input button for that aux 
bus on any aux panel. Chop must be enabled on the rear of the 
Remote Aux Control Panel.