Audiovox CA2051 Istruzione Sull'Installazione

Pagina di 16
8
ca2051 rev B. 2011 Audiovox Electronics Corporation. All rights reserved.
6 Pin Door Lock Output Harness
1
BROWN/BLACK
UNLOCK SWITCH ( 87A )
2
BLUE/BLACK
UNLOCK MOTOR ( 30 )
3
VIOLET/BLACK
UNLOCK POLARITY ( 87 )
4
WHITE/BLACK
LOCK SWITCH ( 87A )
5
GREEN/BLACK
LOCK MOTOR ( 30 )
6
VIOLET
LOCK POLARITY ( 87 )
The door lock / unlock outputs are designed to control several different types of
systems which may require additional parts.
3 Wire Ground Switched Door Locks:
Connect the GREEN/BLACK wire to the wire that provides a ground signal from
the factory door lock switch to the factory door lock control relay.
Connect the BLUE/BLACK wire to the wire that provides a ground signal from the
factory door unlock switch to the factory door lock control relay.
Connect the VIOLET and the VIOLET/BLACK wires to a solid chassis ground
point. The WHITE/BLACK and BROWN/BLACK wires are not required for this type
of door lock/unlock system.
3 Wire Positive Switched Door Locks:
Connect the GREEN/BLACK wire to the wire that provides a +12 volt signal from
the factory door lock switch to the factory door lock control relay.
Connect the BLUE/BLACK wire to the wire that provides a +12 volt signal from
the factory door unlock switch to the factory door lock control relay.
Connect the VIOLET and the VIOLET/BLACK wires to a +12 volt battery source.
The WHITE/BLACK and BROWN/BLACK wires are not required for this type of
door lock/unlock system.