6 Pin Door Lock Output Harness
1
BROWN/BLACK
UNLOCK SWITCH ( 87A )
2
BLUE/BLACK
UNLOCK MOTOR ( 30 )
3
VIOLET/BLACK
UNLOCK POLARITY ( 87 )
4
WHITE/BLACK
LOCK SWITCH ( 87A )
5
GREEN/BLACK
LOCK MOTOR ( 30 )
6
VIOLET
LOCK POLARITY ( 87 )
The door lock / unlock outputs are designed to control several different types of
systems which may require additional parts.
systems which may require additional parts.
3 Wire Ground Switched Door Locks:
Connect the GREEN/BLACK wire to the wire that provides a ground signal from
the factory door lock switch to the factory door lock control relay.
the factory door lock switch to the factory door lock control relay.
Connect the BLUE/BLACK wire to the wire that provides a ground signal from the
factory door unlock switch to the factory door lock control relay.
factory door unlock switch to the factory door lock control relay.
Connect the VIOLET and the VIOLET/BLACK wires to a solid chassis ground
point. The WHITE/BLACK and BROWN/BLACK wires are not required for this type
of door lock/unlock system.
point. The WHITE/BLACK and BROWN/BLACK wires are not required for this type
of door lock/unlock system.
3 Wire Positive Switched Door Locks:
Connect the GREEN/BLACK wire to the wire that provides a +12 volt signal from
the factory door lock switch to the factory door lock control relay.
the factory door lock switch to the factory door lock control relay.
Connect the BLUE/BLACK wire to the wire that provides a +12 volt signal from
the factory door unlock switch to the factory door lock control relay.
the factory door unlock switch to the factory door lock control relay.
Connect the VIOLET and the VIOLET/BLACK wires to a +12 volt battery source.
The WHITE/BLACK and BROWN/BLACK wires are not required for this type of
door lock/unlock system.
The WHITE/BLACK and BROWN/BLACK wires are not required for this type of
door lock/unlock system.