American Megatrends MegaRAID Express 500 Manuale Utente

Pagina di 118
MegaRAID Express 500 Hardware Guide
8
RAID Overview
RAID (Redundant Array of Independent Disks) is a collection of specifications
that describe a system for ensuring the reliability and stability of data stored on
large disk subsystems. A RAID system can be implemented in a number of
different versions (or RAID Levels). The standard RAID levels are 0, 1, 3, and
5. MegaRAID Express 500 supports all standard RAID levels and RAID levels
10, 30, and 50, special RAID versions supported by MegaRAID Express 500.
Consistency Check
In RAID, check consistency verifies the correctness of redundant data in an
array. For example, in a system with dedicated parity, checking consistency
means computing the parity of the data drives and comparing the results to the
contents of the dedicated parity drive.
Fault Tolerance
Fault tolerance is achieved through cooling fans, power supplies, and the ability
to hot swap drives. MegaRAID Express 500 provides hot swapping through the
hot spare feature. A hot spare drive is an unused online available drive that
MegaRAID Express 500 instantly plugs into the system when an active drive
fails.
After the hot spare is automatically moved into the RAID subsystem, the failed
drive is automatically rebuilt. The RAID disk array continues to handle request
while the rebuild occurs.